SKADS-155 Page No. [1] [2] Current PageNo. 1
Features:
Universal AC input / Full rang.
Protections:Short circuit/Over load/Over voltag.
Battery low and battery polarity protectio.
Cooling by free air convection.
100% full load burn-in tes.
Fixed switching frequency at PFC 67KHz, PWM 134KHz.
2 years warranty.
SPECIFICATION
MODEL SKADS-15512 SKADS-15524 SKADS-15548
OUTPUT DC VOLTAGE 12V 5V 24V 5V 48V 5V
RATED CURRENT 11.5A 3A 5.8A 3A 2.9A 3A
CURRENT RANGE 0 ~ 12.5A 0 ~ 3A 0 ~ 6.5A 0 ~ 3A 0 ~ 3.2A 0 ~ 3A
RATED POWER 153W 154.2W 154.2W
RIPPLE & NOISE (max.) Note.2 150mVp-p 100mVp-p 150mVp-p 100mVp-p 240mVp-p 100mVp-p
VOLTAGE ADJ. RANGE CH1:10.8 ~ 13.2V CH1:21.6 ~ 26.4V CH1:43.2 ~ 52.8V
VOLTAGE TOLERANCE Note.3 ¡À2.0% ¡À3.0% ¡À1.0% ¡À3.0% ¡À1.0% ¡À5.0%
LINE REGULATION ¡À0.5% ¡À0.5% ¡À0.5% ¡À¡À0.5% ¡À0.5% ¡À0.5%
LOAD REGULATION ¡À1.0% ¡À2.0% ¡À0.5% ¡À2.0% ¡À1.0% ¡À1.0%
SETUP, RISE, HOLD TIME 1s,90ms,20ms/230VAC    2s,90ms,16ms/115VAC at full load
INPUT VOLTAGE RANGE 88 ~ 264VAC    124 ~ 370VDC
FREQUENCY RANGE 47 ~ 63HZ
POWER FACTOR PF>0.92
EFFICIENCY (Typ.) 77% 82% 82%
AC CURRENT 2.5A/115VAC    1.5A/230VAC
INRUSH CURRENT (max.) COLD START 20A/115VAC     40A/230VAC
LEAKAGE CURRENT <1mA/240VAC
PROTECTION OVERLOAD 105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is reoved
OVER VOLTAGE CH1:13.8 ~ 16.2V CH1:27.6 ~ 32.4V CH1:55.2 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
ENVIRONMENT WORKING TEMP. -10 ~ +60 (Refer to output load derating curve)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT 0.03%/ (0 ~ 50)
VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC (Note 4) SAFETY STANDARDS UL1950 TUV EN60950 Approved
WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT Compliance to EN61000-3-2,-3
EMS IMMUNITY CH1:62.1 ~ 72.9V
OTHERS MTBF 202.3K hrs min. MIL-HDBK-217F (25¡æ)
DIMENSION 199*110*50mm (L*W*H)
PACKING 1Kg; 15pcs/15Kg/1CUFT
NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 2. of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment mus. be re-confirmed that it still meet.
EMC directives.