Features:
Univers al AC input / Full range.
Protections:Short circuit/Over load/Over voltage.
Battery low/Batteryp olarity protections.
Cooling b y free air convection
100% full load burn-in test.
Fixed switching frequency at 54KHz.
2 years warranty.
SPECIFICATION
MODEL SKADS-5512 SKADS-5524
OUTPUT DC VOLTAGE 12V 5V 24V 5V
RATED CURRENT 3A 3A 2A 2A
CURRENT RANGE 0 ~ 4A 0 ~ 4A 0 ~ 2.5A 0 ~ 4A
RATED POWER 51W 58W
RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 100mVp-p 100mVp-p
VOLTAGE ADJ. RANGE CH1:10.8 ~ 13.2V CH1:21.6 ~ 26.4V
VOLTAGE TOLERANCE Note.3 ¡À1.0% ¡À3.0% ¡À1.0% ¡À3.0%
LINE REGULATION ¡À0.5% ¡À0.5% ¡À1.0% ¡À0.5%
LOAD REGULATION ¡À0.5% ¡À0.5% ¡À1.0% ¡À0.5%
SETUP, RISE, HOLD TIME 800ms, 50ms, 60ms/230VAC 1.6s, 50ms, 16ms/115VAC at full load
INPUT VOLTAGE RANGE 88 ~ 264VAC 124 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.) 74% 74%
AC CURRENT 1.6A/115VAC 1A/230VAC
INRUSH CURRENT (max.) COLD START 35A
LEAKAGE CURRENT <3.5mA / 240VAC
PROTECTION OVERLOAD 105 ~ 135% rated output power.
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
OVER VOLTAGE CH1:5.75 ~ 6.75VDC
Protection type : Shut down o/p voltage, re-power on to recover.
ENVIRONMENT WORKING TEMP. -10 ~ +60¡æ (Refer to output load derating curve)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -20 ~ +85¡æ , 10 ~ 95% RH
TEMP. COEFFICIENT ¡À0.03%/ (0 ~ 50) on +5V output
VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC (Note 4) SAFETY STANDARDS UL1950, TUV EN60950 Approved
WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT Compliance to EN61000-3-2,-3
EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
OTHERS MTBF 276.3K hrs min. MIL-HDBK-217F (25¡æ)
DIMENSION 159*97*38mm (L*W*H)
PACKING 0.57Kgs/pcs, 24pcs/13.7Kgs/0.75CUFT
NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wireterminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.