| MODEL |
SKPS-280-13.5 |
SKPS-280-27 |
| |
| OUTPUT |
DC VOLTAGE |
13.5V |
27V |
| RATED CURRENT |
20A |
10A |
| CURRENT RANGE |
0 ~ 20A |
0 ~ 10A |
| RATED POWER |
270W |
270W |
| RIPPLE & NOISE (max.) Note.2 |
150mVp-p |
150mVp-p |
| VOLTAGE ADJ. RANGE |
12 ~ 15V |
24 ~ 30V |
| VOLTAGE TOLERANCE Note.3 |
¡À1.0% |
¡À1.0% |
| LINE REGULATION |
¡À0.5% |
¡À0.5% |
| LOAD REGULATION |
¡À0.5% |
¡À0.5% |
| SETUP, RISE, HOLD TIME |
200ms, 50ms, 10ms |
|
|
| INPUT |
VOLTAGE RANGE |
90 ~ 132VAC / 180 ~ 264VAC By switching 254 ~ 370VDC |
| FREQUENCY RANGE |
47 ~ 63Hz |
| EFFICIENCY (Typ.) |
80% |
82% |
| AC CURRENT |
5.5A/115VAC 3A/230VAC |
| INRUSH CURRENT (max.) |
25A/115VAC 50A/230VACCOLD START 35A |
| LEAKAGE CURRENT |
<1mA / 240VAC |
| |
| PROTECTION |
OVERLOAD |
105 ~ 135% rated output power (150 ~ 200% rated output power for S-100-7.5 only) |
| Protection type : Fold back current limiting, recovers automatically after fault condition is removed. |
| OVER VOLTAGE |
15.53 ~ 18.23V |
31.05 ~ 36.45V |
| Protection type : Constant voltage limiting, recovers automatically after fault condition is removed. |
| FUNCTION |
FAN CONTROL O.T.P. |
RTH3 60 FAN ON, 50 FAN OFF, 90 output shutdown |
| |
| ENVIRONMENT |
WORKING TEMP.,HUMIDITY |
-10 ~ +60¡æ (Refer to output load derating curve), 20 ~ 90% RH |
| STORAGE TEMP., HUMIDITY |
-20 ~ +85¡æ, 10 ~ 95% RH |
| TEMP. COEFFICIENT |
¡À0.03%/¡æ (0 ~ 50¡æ) |
| VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
| |
| SAFETY & EMC |
SAFETY STANDARDS |
UL1012 Approved |
| EMI CONDUCTION & RADIATION |
Design refer to FCC Part15 J Conduction Class B |
| WITHSTAND VOLTAGE |
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
| |
| OTHERS |
MTBF |
209.4K hrs min. MIL-HDBK-217F (25¡æ) |
| DIMENSION |
150*140*86mm (L*W*H) |
| PACKING |
1.43Kgs/pcs, 8pcs/11.44Kgs/0.97CUFT |
| |
| NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation. |
| |