| MODEL |
SKS-100F-5 |
SKS-100F-7.5 |
SKS-100F-12 |
SKS-100F-15 |
SKS-100F-24 |
SKS-100F-48 |
| |
| OUTPUT |
DC VOLTAGE |
5V |
7.5V |
12V |
15V |
24V |
48V |
| RATED CURRENT |
20A |
13.5A |
8.5A |
6.7A |
4.5A |
2.2A |
| CURRENT RANGE |
0 ~ 20A |
0 ~ 13.5A |
0 ~ 8.5A |
0 ~ 6.7A |
0 ~ 4.5A |
0 ~ 2.2A |
| RATED POWER |
100W |
101W |
102W |
100.5W |
108W |
105.6W |
| RIPPLE & NOISE (max.) Note.2 |
110mVp-p |
125mVp-p |
125mVp-p |
125mVp-p |
150mVp-p |
150mVp-p |
| VOLTAGE ADJ. RANGE |
4.5 ~ 5.5V |
6.75 ~ 8.25V |
10.8 ~ 13.2V |
13.5 ~ 16.5V |
21.6 ~ 26.4V |
43.2 ~ 52.8V |
| VOLTAGE TOLERANCE Note.3 |
¡À2.0% |
¡À1.0% |
¡À1.0% |
¡À1.0% |
¡À1.0% |
¡À1.0% |
| LINE REGULATION |
¡À0.5% |
¡À0.5% |
¡À0.5% |
¡À0.5% |
¡À0.5% |
¡À0.5% |
| LOAD REGULATION |
¡À1.0% |
¡À0.5% |
¡À0.5% |
¡À0.5% |
¡À0.5% |
¡À0.5% |
| SETUP, RISE, HOLD TIME |
1s, 30ms, 15ms at full load |
|
|
| INPUT |
VOLTAGE RANGE |
88 ~ 132VAC/176 ~ 264VAC selected by jumper or switch 248 ~ 370VDC |
| FREQUENCY RANGE |
47 ~ 63Hz |
| EFFICIENCY (Typ.) |
76% |
78% |
80% |
81% |
83% |
84% |
| AC CURRENT |
2.4A/115VAC 1.2A/230VAC |
| INRUSH CURRENT (max.) |
COLD START 30A/115VAC 60A/230VAC |
| LEAKAGE CURRENT |
<1mA / 240VAC |
| |
| PROTECTION |
OVERLOAD |
105 ~ 150% rated output power |
| Protection type : Hiccup mode, recovers automatically after fault condition is removed. |
| OVER VOLTAGE |
5.75 ~ 6.75V |
8.63 ~ 10.13V |
13.8 ~ 16.2V |
17.25 ~ 20.25V |
27.6 ~ 32.4V |
55.2 ~ 64.8V |
| Protection type : Hiccup mode, recovers automatically after fault condition is removed. |
| |
| ENVIRONMENT |
WORKING TEMP. |
-10 ~ +60¡æ (Refer to output load derating curve) |
| WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
| STORAGE TEMP., HUMIDITY |
-20 ~ +85¡æ , 10 ~ 95% RH |
| TEMP. COEFFICIENT |
¡À0.03%/ (0 ~ 50¡æ) |
| VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
| |
| SAFETY & EMC
(Note 4) |
SAFETY STANDARDS |
UL1012, UL1950, TUV EN60950 Approved |
| WITHSTAND VOLTAGE |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
| EMI CONDUCTION & RADIATION |
Compliance to EN55022 (CISPR22) Class B |
| ARMONIC CURRENT |
Compliance to EN61000-3-2,-3 |
| EMS IMMUNITY |
Compliance to EN61000-4-2,3,4,5; ENV50204, EN55024, Light industry level, criteria A |
| |
| OTHERS |
MTBF |
314.9K hrs min. MIL-HDBK-217F (25¡æ) |
| DIMENSION |
199*98*38mm (L*W*H) |
| PACKING |
0.65Kg; 20pcs/13Kg/0.89CUFT |
| |
| NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 2. of
ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final
equipment. The final equipment mus. be re-confirmed that it still meet.
EMC directives. |
| |