SKS-15 Page No. [1] [2] Current PageNo. 1
Features:
AC input range selected by switch.
Protections:Short circuit/Over load.
Cooling by free air convection.
100% full load burn-in.
Fixed switching frequency at 37KHz.
Lost cost.
High reliability.
1 year warranty.
SPECIFICATION
MODEL SKS-15-5 SKS-15-12 SKS-15-24
OUTPUT DC VOLTAGE 5V 12V 24V
RATED CURRENT 3A 1.3A 0.7A
CURRENT RANGE 0 ~ 3A 0 ~ 1.3A 0 ~ 0.7A
RATED POWER 15W 15.6W 16.8W
RIPPLE & NOISE (max.) Note.2 50mVp-p 50mVp-p 100mVp-p
VOLTAGE ADJ. RANGE 4.75 ~ 5.5V 10.8 ~ 13.2V 21.6 ~ 26.4V
VOLTAGE TOLERANCE Note.3 ¡À2.0% ¡À1.0% ¡À1.0%
LINE REGULATION ¡À0.5% ¡À0.5% ¡À0.5%
LOAD REGULATION ¡À1.0% ¡À0.5% ¡À0.5%
SETUP, RISE, HOLD TIME 200ms, 100ms, 30ms at full load
INPUT VOLTAGE RANGE 85 ~ 132VAC / 170 ~ 264VAC selected by switch 240 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.) 65% 68% 72%
AC CURRENT 0.5A/115VAC 0.25A/230VAC
INRUSH CURRENT (max.) COLD START 15A/115VAC 30A/230VAC
LEAKAGE CURRENT <0.5mA/240VAC
PROTECTION OVERLOAD 105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is reoved
ENVIRONMENT WORKING TEMP. -10 ~ +60¡æ (Refer to output load derating curve)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -20 ~ +85¡æ , 10 ~ 95% RH
TEMP. COEFFICIENT ¡À0.02%/ (0 ~ 50)
VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC (Note 4) SAFETY STANDARDS Design refer to UL1012
WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION Design refer to FCC Part15 J Conduction Class B
OTHERS MTBF 522.1K hrs min. MIL-HDBK-217F (25¡æ)
DIMENSION 99*97*35mm (L*W*H)
PACKING 0.31Kg; 45pcs/14Kg/0.9CUFT
NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 2. of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.